Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Antigen discovery by bioinformatics analysis and peptide microarray for the diagnosis of cystic echinococcosis

Batisti Biffignandi, Gherard; Vola, Ambra; Sassera, Davide; Najafi-Fard, Saeid; Gomez Morales, Maria Angeles; Brunetti, Enrico; Teggi, Antonella; Goletti, Delia; Petrone, Linda; Tamarozzi, Francesca
PLoS Negl Trop Dis.
Apr 2023
Background Cystic echinococcosis (CE), caused by Echinococcus granulosus sensu lato, is a neglected zoonosis. Its diagnosis relies on imaging, supported by serology, while only imaging is useful for staging and follow-up. Since diagnostic tools and expertise are not widely available, new accurate and easily implementable assays for the diagnosis and follow-up of CE are highly needed. Methodology/Principal Findings We aimed to identify new E . granulosus antigens through a bioinformatics selection applied to the parasite genome, followed by peptide microarray screening and validation in ELISA, using independent panels of sera from patients with hepatic CE and clinically relevant controls. From 950 proteins selected in silico , 2,379 peptides were evaluated by microarray for IgG reactivity and eight candidates selected for validation. Reactivity to one peptide was significantly higher in the CE group (p = 0.044), but had suboptimal diagnostic accuracy. Conclusions/Significance Here we performed bioinformatics analysis and peptide microarray for antigen discovery, useful for the diagnosis of CE. Eight candidates were selected and validated. Reactivity to one peptide associated to CE but had suboptimal diagnostic accuracy. Importantly, the database developed in this study may be used to identify other antigenic candidates for CE diagnosis and follow-up.

Combinatorial Synthesis of Macromolecular Arrays by Microchannel Cantilever Spotting (µCS)

Atwater, Jordyn; Mattes, Daniela S.; Streit, Bettina; von Bojničić-Kninski, Clemens; Loeffler, Felix F.; Breitling, Frank; Fuchs, Harald; Hirtz, Michael
Adv. Mater..
Aug 2018
Surface-bound microarrays of multiple oligo- and macromolecules (e.g., peptides, DNA) offer versatile options in biomedical applications like drug screening, DNA analysis, or medical diagnostics. Combinatorial syntheses of these molecules in situ can save significant resources in regard to processing time and material use. Furthermore, high feature densities are needed to enable high-throughput and low sample volumes as generally regarded in combinatorial chemistry. Here, a scanning-probe-lithography-based approach for the combinatorial in situ synthesis of macromolecules is presented in microarray format. Feature sizes below 40 µm allow for the creation of high-density arrays with feature densities of 62 500 features per cm2. To demonstrate feasibility of this approach for biomedical applications, a multiplexed array of functional protein tags (HA- and FLAG-tag) is synthesized, and selective binding of respective epitope recognizing antibodies is shown. This approach uses only small amounts of base chemicals for synthesis and can be further parallelized, therefore, opening up a route to flexible, highly dense, and cost-effective microarrays.

Reductionist Approach in Peptide-Based Nanotechnology

Gazit, Ehud
Annu. Rev. Biochem..
Jun 2018
The formation of ordered nanostructures by molecular self-assembly of proteins and peptides represents one of the principal directions in nanotechnology. Indeed, polyamides provide superior features as materials with diverse physical properties. A reductionist approach allowed the identification of extremely short peptide sequences, as short as dipeptides, which could form well-ordered amyloid-like β-sheet-rich assemblies comparable to supramolecular structures made of much larger proteins. Some of the peptide assemblies show remarkable mechanical, optical, and electrical characteristics. Another direction of reductionism utilized a natural noncoded amino acid, α-aminoisobutryic acid, to form short superhelical assemblies. The use of this exceptional helix inducer motif allowed the fabrication of single heptad repeats used in various biointerfaces, including their use as surfactants and DNA-binding agents. Two additional directions of the reductionist approach include the use of peptide nucleic acids (PNAs) and coassembly techniques. The diversified accomplishments of the reductionist approach, as well as the exciting future advances it bears, are discussed.

A Trifunctional Linker for Purified 3D Assembled Peptide Structure Arrays

Mattes, Daniela S.; Rentschler, Simone; Foertsch, Tobias C.; Münch, Stephan W.; Loeffler, Felix F.; Nesterov-Mueller, Alexander; Bräse, Stefan; Breitling, Frank
Small Methods.
Feb 2018
Microarrays are an important tool in modern research that allow the rapid screening of many different interactions simultaneously. Peptide arrays, which bear different peptides arranged in separate spots, permit high-throughput screening to investigate linear and cyclic binding sites. To study conformational or discontinuous binding sites, protein arrays are the major choice. However, the tremendous costs for the generation of high-density protein arrays of high purity restrict progress in protein research. Therefore, peptide-based arrays, which can mimic assembled peptide structures, have an enormous potential. Here, a method is presented to create such structures in the array format as an alternative to protein arrays. A trifunctional linker is developed with an azide, a protected alkyne, and a carboxyl group, which can react with two or three different peptides. Due to the spatial proximity, the peptides interact and can form an assembled peptide structure. As a proof of concept, assembled peptide structures are demonstrated on beads and on a polymer surface and the approach can be validated via matrix-assisted laser desorption/ionization spectrometry. Furthermore, a multistep transfer of peptide arrays is shown, generating purified assembled peptide structure arrays in high density.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Optimised ‘on demand’ protein arraying from DNA by cell free expression with the ‘DNA to Protein Array’ (DAPA) technology

Schmidt, Ronny; Cook, Elizabeth A.; Kastelic, Damjana; Taussig, Michael J.; Stoevesandt, Oda
Journal of Proteomics.
Aug 2013
We have previously described a protein arraying process based on cell free expression from DNA template arrays (DNA Array to Protein Array, DAPA). Here, we have investigated the influence of different array support coatings (Ni-NTA, Epoxy, 3D-Epoxy and Polyethylene glycol methacrylate (PEGMA)). Their optimal combination yields an increased amount of detected protein and an optimised spot morphology on the resulting protein array compared to the previously published protocol. The specificity of protein capture was improved using a tag-specific capture antibody on a protein repellent surface coating. The conditions for protein expression were optimised to yield the maximum amount of protein or the best detection results using specific monoclonal antibodies or a scaffold binder against the expressed targets. The optimised DAPA system was able to increase by threefold the expression of a representative model protein while conserving recognition by a specific antibody. The amount of expressed protein in DAPA was comparable to those of classically spotted protein arrays. Reaction conditions can be tailored to suit the application of interest. Biological significance: DAPA represents a cost effective, easy and convenient way of producing protein arrays on demand. The reported work is expected to facilitate the application of DAPA for personalized medicine and screening purposes.

Purification of High-Complexity Peptide Microarrays by Spatially Resolved Array Transfer to Gold-Coated Membranes

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Nesterov-Mueller, Alexander; Dahint, Reiner; Breitling, Frank; Bischoff, F. Ralf
Adv. Mater..
Mar 2013
A method for the one-step purification of high-complexity peptide microarrays is presented. The entire peptide library is transferred from the synthesis support to a gold coated polyvinylidenfluoride (PVDF) membrane, whereby only full-length peptides covalently couple to the receptor membrane via an N-terminally added cysteine. Highly resolved peptide transfer and purification of up to 10 000 features per cm2 is demonstrated.

Sensing Immune Responses with Customized Peptide Microarrays

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Breitling, Frank; Bischoff, F. Ralf
Biointerphases.
Aug 2012
The intent to solve biological and biomedical questions in high-throughput led to an immense interest in microarray technologies. Nowadays, DNA microarrays are routinely used to screen for oligonucleotide interactions within a large variety of potential interaction partners. To study interactions on the protein level with the same efficiency, protein and peptide microarrays offer similar advantages, but their production is more demanding. A new technology to produce peptide microarrays with a laser printer provides access to affordable and highly complex peptide microarrays. Such a peptide microarray can contain up to 775 peptide spots per cm², whereby the position of each peptide spot and, thus, the amino acid sequence of the corresponding peptide, is exactly known. Compared to other techniques, such as the SPOT synthesis, more features per cm² at lower costs can be synthesized which paves the way for laser printed peptide microarrays to take on roles as efficient and affordable biomedical sensors. Here, we describe the laser printer-based synthesis of peptide microarrays and focus on an application involving the blood sera of tetanus immunized individuals, indicating the potential of peptide arrays to sense immune responses.

Physical Characterization of the “Immunosignaturing Effect”

Stafford, Phillip; Halperin, Rebecca; Legutki, Joseph Bart; Magee, Dewey Mitchell; Galgiani, John; Johnston, Stephen Albert
Mol Cell Proteomics.
Apr 2012
Identifying new, effective biomarkers for diseases is proving to be a challenging problem. We have proposed that antibodies may offer a solution to this problem. The physical features and abundance of antibodies make them ideal biomarkers. Additionally, antibodies are often elicited early in the ontogeny of different chronic and infectious diseases. We previously reported that antibodies from patients with infectious disease and separately those with Alzheimer’s disease display a characteristic and reproducible immunosignature on a microarray of 10,000 random sequence peptides. Here we investigate the physical and chemical parameters underlying how immunosignaturing works. We first show that a variety of monoclonal and polyclonal antibodies raised against different classes of antigens produce distinct profiles on this microarray and the relative affinities are determined. A proposal for how antibodies bind the random sequences is tested. Sera from vaccinated mice and people suffering from a fugal infection are individually assayed to determine the complexity of signals that can be distinguished. Based on these results, we propose that this simple, general and inexpensive system could be optimized to generate a new class of antibody biomarkers for a wide variety of diseases.

Quote form