Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

HSP70iQ435A to subdue autoimmunity and support anti-tumor responses

Jaishankar, Dinesh; Cosgrove, Cormac; Ramesh, Prathyaya; Mahon, James; Shivde, Rohan; Dellacecca, Emilia R.; Yang, Shiayin F.; Mosenson, Jeffrey; Guevara-Patiño, José A.; Le Poole, I. Caroline
Cell Stress and Chaperones.
Sep 2021
Developing immunosuppressive therapies for autoimmune diseases comes with a caveat that immunosuppression may promote the risk of developing other conditions or diseases. We have previously shown that biolistic delivery of an expression construct encoding inducible HSP70 (HSP70i) with one amino acid modification in the dendritic cell (DC) activating moiety 435–445 (HSP70iQ435A) to mouse skin resulted in significant immunosuppressive activity of autoimmune vitiligo, associated with fewer tissue infiltrating T cells. To prepare HSP70iQ435A as a potential therapeutic for autoimmune vitiligo, in this study we evaluated whether and how biolistic delivery of HSP70iQ435A in mice affects anti-tumor responses. We found that HSP70iQ435A in fact supports anti-tumor responses in melanoma-challenged C57BL/6 mice. Biolistic delivery of the HSP70iQ435A-encoding construct to mice elicited significant anti-HSP70 titers, and anti-HSP70 IgG and IgM antibodies recognize surface-expressed and cytoplasmic HSP70i in human and mouse melanoma cells. A peptide scan revealed that the anti-HSP70 antibodies recognize a specific C-terminal motif within the HSP70i protein. The antibodies elicited surface CD107A expression among mouse NK cells, representative of antibody-mediated cellular cytotoxicity (ADCC), supporting the concept, that HSP70iQ435A-encoding DNA elicits a humoral response to the stress protein expressed selectively on the surface of melanoma cells. Thus, besides limiting autoimmunity and inflammation, HSP70iQ435A elicits humoral responses that limit tumor growth and may be used in conjunction with immune checkpoint inhibitors to not only control tumor but to also limit adverse events following tumor immunotherapy.

Serum Peptide Immunoglobulin G Autoantibody Response in Patients with Different Central Nervous System Inflammatory Demyelinating Disorders

Lee, Hye Lim; Park, Jin-Woo; Seok, Jin Myoung; Jeon, Mi Young; Kim, Hojin; Lim, Young-Min; Shin, Ha Young; Kang, Sa-Yoon; Kwon, Oh-Hyun; Lee, Sang-Soo; Seok, Hung Youl; Min, Ju-Hong; Lee, Sung-Hyun; Kim, Byung-Jo; Kim, Byoung Joon
Diagnostics.
Jul 2021
Previous efforts to discover new surrogate markers for the central nervous system (CNS) inflammatory demyelinating disorders have shown inconsistent results; moreover, supporting evidence is scarce. The present study investigated the IgG autoantibody responses to various viral and autoantibodies-related peptides proposed to be related to CNS inflammatory demyelinating disorders using the peptide microarray method. We customized a peptide microarray containing more than 2440 immobilized peptides representing human and viral autoantigens. Using this, we tested the sera of patients with neuromyelitis optica spectrum disorders (NMOSD seropositive, n = 6; NMOSD seronegative, n = 5), multiple sclerosis (MS, n = 5), and myelin-oligodendrocyte glycoprotein antibody-associated disease (MOGAD, n = 6), as well as healthy controls (HC, n = 5) and compared various peptide immunoglobulin G (IgG) responses between the groups. Among the statistically significant peptides based on the pairwise comparisons of IgG responses in each disease group to HC, cytomegalovirus (CMV)-related peptides were most clearly distinguishable among the study groups. In particular, the most significant differences in IgG response were observed for HC vs. MS and HC vs. seronegative NMOSD (p = 0.064). Relatively higher IgG responses to CMV-related peptides were observed in patients with MS and NMOSD based on analysis of the customized peptide microarray.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

General Approach for Tetramer-Based Identification of Autoantigen-Reactive B Cells: Characterization of La- and snRNP-Reactive B Cells in Autoimmune BXD2 Mice

Hamilton, Jennie A.; Li, Jun; Wu, Qi; Yang, PingAr; Luo, Bao; Li, Hao; Bradley, John E.; Taylor, Justin J.; Randall, Troy D.; Mountz, John D.; Hsu, Hui-Chen
J.I..
May 2015
Autoreactive B cells are associated with the development of several autoimmune diseases, including systemic lupus erythematosus and rheumatoid arthritis. The low frequency of these cells represents a major barrier to their analysis. Ag tetramers prepared from linear epitopes represent a promising strategy for the identification of small subsets of Ag-reactive immune cells. This is challenging given the requirement for identification and validation of linear epitopes and the complexity of autoantibody responses, including the broad spectrum of autoantibody specificities and the contribution of isotype to pathogenicity. Therefore, we tested a two-tiered peptide microarray approach, coupled with epitope mapping of known autoantigens, to identify and characterize autoepitopes using the BXD2 autoimmune mouse model. Microarray results were verified through comparison with established age-associated profiles of autoantigen specificities and autoantibody class switching in BXD2 and control (C57BL/6) mice and high-throughput ELISA and ELISPOT analyses of synthetic peptides. Tetramers were prepared from two linear peptides derived from two RNA-binding proteins (RBPs): lupus La and 70-kDa U1 small nuclear ribonucleoprotein. Flow cytometric analysis of tetramer-reactive B cell subsets revealed a significantly higher frequency and greater numbers of RBP-reactive marginal zone precursor, transitional T3, and PDL-2+CD80+ memory B cells, with significantly elevated CD69 and CD86 observed in RBP+ marginal zone precursor B cells in the spleens of BXD2 mice compared with C57BL/6 mice, suggesting a regulatory defect. This study establishes a feasible strategy for the characterization of autoantigen-specific B cell subsets in different models of autoimmunity and, potentially, in humans.

Optimised ‘on demand’ protein arraying from DNA by cell free expression with the ‘DNA to Protein Array’ (DAPA) technology

Schmidt, Ronny; Cook, Elizabeth A.; Kastelic, Damjana; Taussig, Michael J.; Stoevesandt, Oda
Journal of Proteomics.
Aug 2013
We have previously described a protein arraying process based on cell free expression from DNA template arrays (DNA Array to Protein Array, DAPA). Here, we have investigated the influence of different array support coatings (Ni-NTA, Epoxy, 3D-Epoxy and Polyethylene glycol methacrylate (PEGMA)). Their optimal combination yields an increased amount of detected protein and an optimised spot morphology on the resulting protein array compared to the previously published protocol. The specificity of protein capture was improved using a tag-specific capture antibody on a protein repellent surface coating. The conditions for protein expression were optimised to yield the maximum amount of protein or the best detection results using specific monoclonal antibodies or a scaffold binder against the expressed targets. The optimised DAPA system was able to increase by threefold the expression of a representative model protein while conserving recognition by a specific antibody. The amount of expressed protein in DAPA was comparable to those of classically spotted protein arrays. Reaction conditions can be tailored to suit the application of interest. Biological significance: DAPA represents a cost effective, easy and convenient way of producing protein arrays on demand. The reported work is expected to facilitate the application of DAPA for personalized medicine and screening purposes.

Purification of High-Complexity Peptide Microarrays by Spatially Resolved Array Transfer to Gold-Coated Membranes

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Nesterov-Mueller, Alexander; Dahint, Reiner; Breitling, Frank; Bischoff, F. Ralf
Adv. Mater..
Mar 2013
A method for the one-step purification of high-complexity peptide microarrays is presented. The entire peptide library is transferred from the synthesis support to a gold coated polyvinylidenfluoride (PVDF) membrane, whereby only full-length peptides covalently couple to the receptor membrane via an N-terminally added cysteine. Highly resolved peptide transfer and purification of up to 10 000 features per cm2 is demonstrated.

Single-Molecule Detection on a Protein-Array Assay Platform for the Exposure of a Tuberculosis Antigen

Schmidt, Ronny; Jacak, Jaroslaw; Schirwitz, Christopher; Stadler, Volker; Michel, Gerd; Marmé, Nicole; Schütz, Gerhard J.; Hoheisel, Jörg D.; Knemeyer, Jens-Peter
J. Proteome Res..
Jan 2011

Quote form