Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Antigen discovery by bioinformatics analysis and peptide microarray for the diagnosis of cystic echinococcosis

Batisti Biffignandi, Gherard; Vola, Ambra; Sassera, Davide; Najafi-Fard, Saeid; Gomez Morales, Maria Angeles; Brunetti, Enrico; Teggi, Antonella; Goletti, Delia; Petrone, Linda; Tamarozzi, Francesca
PLoS Negl Trop Dis.
Apr 2023
Background Cystic echinococcosis (CE), caused by Echinococcus granulosus sensu lato, is a neglected zoonosis. Its diagnosis relies on imaging, supported by serology, while only imaging is useful for staging and follow-up. Since diagnostic tools and expertise are not widely available, new accurate and easily implementable assays for the diagnosis and follow-up of CE are highly needed. Methodology/Principal Findings We aimed to identify new E . granulosus antigens through a bioinformatics selection applied to the parasite genome, followed by peptide microarray screening and validation in ELISA, using independent panels of sera from patients with hepatic CE and clinically relevant controls. From 950 proteins selected in silico , 2,379 peptides were evaluated by microarray for IgG reactivity and eight candidates selected for validation. Reactivity to one peptide was significantly higher in the CE group (p = 0.044), but had suboptimal diagnostic accuracy. Conclusions/Significance Here we performed bioinformatics analysis and peptide microarray for antigen discovery, useful for the diagnosis of CE. Eight candidates were selected and validated. Reactivity to one peptide associated to CE but had suboptimal diagnostic accuracy. Importantly, the database developed in this study may be used to identify other antigenic candidates for CE diagnosis and follow-up.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Quote form