Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Monoclonal antibodies to HLA-E bind epitopes carried by unfolded β 2 m-free heavy chains: Molecular immunology

Tremante, Elisa; Lo Monaco, Elisa; Ingegnere, Tiziano; Sampaoli, Camilla; Fraioli, Rocco; Giacomini, Patrizio
Eur. J. Immunol..
Aug 2015
Since HLA-E heavy chains accumulate free of their light β2-microglobulin (β2m) subunit, raising mAbs to folded HLA-E heterodimers has been difficult, and mAb characterization has been controversial. Herein, mAb W6/32 and 5 HLA-E-restricted mAbs (MEM-E/02, MEM-E/07, MEM-E/08, DT9, and 3D12) were tested on denatured, acid-treated, and natively folded (both β2m-associated and β2m-free) HLA-E molecules. Four distinct conformations were detected, including unusual, partially folded (and yet β2m-free) heavy chains reactive with mAb DT9. In contrast with previous studies, epitope mapping and substitution scan on thousands of overlapping peptides printed on microchips revealed that mAbs MEM-E/02, MEM-E/07, and MEM-E/08 bind three distinct α1 and α2 domain epitopes. All three epitopes are linear since they span just 4–6 residues and are “hidden” in folded HLA-E heterodimers. They contain at least one HLA-E-specific residue that cannot be replaced by single substitutions with polymorphic HLA-A, HLA-B, HLA-C, HLA-F, and HLA-G residues. Finally, also the MEM-E/02 and 3D12 epitopes are spatially distinct. In summary, HLA-E-specific residues are dominantly immunogenic, but only when heavy chains are locally unfolded. Consequently, the available mAbs fail to selectively bind conformed HLA-E heterodimers, and HLA-E expression may have been inaccurately assessed in some previous oncology, reproductive immunology, virology, and transplantation studies.

Printed peptide arrays identify prognostic TNC serumantibodies in glioblastoma patients

Mock, Andreas; Warta, Rolf; Geisenberger, Christoph; Bischoff, Ralf; Schulte, Alexander; Lamszus, Katrin; Stadler, Volker; Felgenhauer, Thomas; Schichor, Christian; Schwartz, Christoph; Matschke, Jakob; Jungk, Christine; Ahmadi, Rezvan; Sahm, Felix; Capper, David; Glass, Rainer; Tonn, Jörg-Christian; Westphal, Manfred; von Deimling, Andreas; Unterberg, Andreas; Bermejo, Justo Lorenzo; Herold-Mende, Christel
Oncotarget.
May 2015
Liquid biopsies come of age offering unexploited potential to monitor and react to tumor evolution. We developed a cost-effective assay to non-invasively determine the immune status of glioblastoma (GBM) patients. Employing newly developed printed peptide microarrays we assessed the B-cell response against tumor-associated antigens (TAAs) in 214 patients. Firstly, sera of long-term (36+ months, LTS, n=10) and short-term (6-10 months, STS, n=14) surviving patients were screened for prognostic antibodies against 1745 13-mer peptides covering known TAAs (TNC, EGFR, GLEA2, PHF3, FABP5, MAGEA3). Next, survival associations were investigated in two retrospective independent multicenter validation sets (n=61, n=129, all IDH1-wildtype). Reliability of measurements was tested using a second array technology (spotted arrays). LTS/STS screening analyses identified 106 differential antibody responses. Evaluating the Top30 peptides in validation set 1 revealed three prognostic peptides. Prediction of TNC peptide VCEDGFTGPDCAE was confirmed in a second set (p=0.043, HR=0.66 [0.44-0.99]) and was unrelated to TNC protein expression. Median signals of printed arrays correlated with pre-synthesized spotted microarrays (p<0.0002, R=0.33). Multiple survival analysis revealed independence of age, gender, KPI and MGMT status. We present a novel peptide microarray immune assay that identified increased anti-TNC VCEDGFTGPDCAE serum antibody titer as a promising non-invasive biomarker for prolonged survival.

Combinatorial Peptide Synthesis on a Microchip

Schirwitz, Christopher; Block, Ines; König, Kai; Nesterov, Alexander; Fernandez, Simon; Felgenhauer, Thomas; Leibe, Klaus; Torralba, Gloria; Hausmann, Michael; Lindenstruth, Volker; Stadler, Volker; Breitling, Frank; Bischoff, F. Ralf
Current Protocols in Protein Science.
Aug 2009
Microchips are used in the combinatorial synthesis of peptide arrays by means of amino acid microparticle deposition. The surface of custom-built microchips can be equipped with an amino-modified poly(ethylene glycol)methacrylate (PEGMA) graft polymer coating, which permits high loading of functional groups and resists nonspecific protein adsorption. Specific microparticles that are addressed to the polymer-coated microchip surface in a well defined pattern release preactivated amino acids upon melting, and thus allow combinatorial synthesis of high-complexity peptide arrays directly on the chip surface. Currently, arrays with densities of up to 40,000 peptide spots/cm2 can be generated in this way, with a minimum of coupling cycles required for full combinatorial synthesis. Without using any additional blocking agent, specific peptide recognition has been verified by background-free immunostaining on the chip-based array. This unit describes microchip surface modification, combinatorial peptide array synthesis on the chip, and a typical immunoassay employing the resulting high-density peptide arrays.

Particle-Based Synthesis of Peptide Arrays

Breitling, Frank; Felgenhauer, Thomas; Nesterov, Alexander; Lindenstruth, Volker; Stadler, Volker; Bischoff, F. Ralf
ChemBioChem.
Mar 2009
Lithographic methods allow for the combinatorial synthesis of >50,000 oligonucleotides per cm(2), and this has revolutionized the field of genomics. High-density peptide arrays promise to advance the field of proteomics in a similar way, but currently lag behind. This is mainly due to the monomer-by-monomer repeated consecutive coupling of 20 different amino acids associated with lithography, which adds up to an excessive number of coupling cycles. Combinatorial synthesis based on electrically charged solid amino acid particles resolves this problem. A color laser printer or a chip addresses the different charged particles consecutively to a solid support, where, when completed, the whole layer of solid amino acid particles is melted at once. This frees hitherto immobilized amino acids to couple all 20 different amino acids to the support in one single coupling reaction. The method should allow for the translation of entire genomes into sets of overlapping peptides to be used in proteome research.

High-density peptide arrays

Breitling, Frank; Nesterov, Alexander; Stadler, Volker; Felgenhauer, Thomas; Bischoff, F. Ralf
Mol. BioSyst..
Jan 2009
Arrays promise to advance biology by allowing parallel screening for many different binding partners. Meanwhile, lithographic methods enable combinatorial synthesis of >50 000 oligonucleotides per cm2, an advance that has revolutionized the whole field of genomics. A similar development is expected for the field of proteomics, provided that affordable, very high-density peptide arrays are available. However, peptide arrays lag behind oligonucleotide arrays. This review discusses recent developments in the field with an emphasis on methods that lead to very high-density peptide arrays.

Quote form