Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

High-resolution mapping of linear epitopes from LiNTPDase2: Advancing leishmaniasis detection using optimized protein and peptide antigens

Castro, Raissa Barbosa De; Badaró De Moraes, João Victor; De Souza, Anna Cláudia Alves; Favarato, Evandro Silva; Voorwald, Fabiana Azevedo; Dos Santos, Fabiane Matos; Bressan, Gustavo Costa; Vasconcellos, Raphael De Souza; Fietto, Juliana Lopes Rangel
Diagnostic Microbiology and Infectious Disease.
Oct 2024
Visceral Leishmaniasis, caused by Leishmania infantum, is a tropical neglected disease and the most dangerous form of Leishmaniasis. It occurs zoonotically, with domestic transmission posing risks to humans as dogs have high susceptibility and are natural reservoirs of the parasite. Given their epidemiological role, improvements are needed in diagnosing Canine Visceral Leishmaniasis (CVL). Thus, we mapped linear epitopes from the rLiNTPDase2 antigen through peptide microarray and identified six positive epitopes. Validation through peptide ELISA revealed three promising peptides with accuracies of 78.6%, 85.92%, and 79.59%. Their combination yielded 97.58% accuracy. Negative epitopes were also found, which interacted with CVL-negative and Chagas Disease positive samples. Their removal from the rLiNTPDase2 sequence resulted in the rNT2.neg, which obtained enhanced specificity over rLiNTPDase2. The rNT2.neg validation achieved 87.50% sensitivity, 90.55% specificity, and 93.5% accuracy within 127 CVL-positive and 96 CVL-negative samples. Therefore, three peptides and rNT2.neg show significant promise for CVL diagnosis.

Identification of Schistosoma haematobium and Schistosoma mansoni linear B-cell epitopes with diagnostic potential using in silico immunoinformatic tools and peptide microarray technology

Vengesai, Arthur; Manuwa, Marble; Midzi, Herald; Mandeya, Masimba; Muleya, Victor; Mujeni, Keith; Chipako, Isaac; Mduluza, Takafira
PLoS Negl Trop Dis.
Aug 2024
Introduction: Immunoinformatic tools can be used to predict schistosome-specific B-cell epitopes with little sequence identity to human proteins and antigens other than the target. This study reports an approach for identifying schistosome peptides mimicking linear B-cell epitopes using in-silico tools and peptide microarray immunoassay validation. Method: Firstly, a comprehensive literature search was conducted to obtain published schistosome-specific peptides and recombinant proteins with the best overall diagnostic performances. For novel peptides, linear B-cell epitopes were predicted from target recombinant proteins using ABCpred, Bcepred and BepiPred 2.0 in-silico tools. Together with the published peptides, predicted peptides with the highest probability of being B-cell epitopes and the lowest sequence identity with proteins from human and other pathogens were selected. Antibodies against the peptides were measured in sera, using peptide microarray immunoassays. Area under the ROC curve was calculated to assess the overall diagnostic performances of the peptides. Results: Peptide AA81008-19-30 had excellent and acceptable diagnostic performances for discriminating S. mansoni and S. haematobium positives from healthy controls, with AUC values of 0.8043 and 0.7326 respectively for IgG. Peptides MS3_10186-123-131, MS3_10385-339-354, SmSPI-177-193, SmSPI-379-388, MS3-10186-40-49 and SmS-197-214 had acceptable diagnostic performances for discriminating S. mansoni positives from healthy controls with AUC values ranging from 0.7098 to 0.7763 for IgG. Peptides SmSPI-359-372, Smp126160-438-452 and MS3 10186-25-41 had acceptable diagnostic performances for discriminating S. mansoni positives from S. mansoni negatives with AUC values of 0.7124, 0.7156 and 0.7115 respectively for IgG. Peptide MS3-10186-40-49 had an acceptable diagnostic performance for discriminating S. mansoni positives from healthy controls, with an AUC value of 0.7413 for IgM. Conclusion: One peptide with a good diagnostic performance and nine peptides with acceptable diagnostic performances were identified using the immunoinformatic approach and peptide microarray validation. There is need for evaluation of the peptides with true negatives and a good standard positive reference.

Alzheimer’s disease risk associated with changes in Epstein-Barr virus nuclear antigen 1-specific epitope targeting antibody levels

Sim, Kyu-Young; An, Jaekyeung; Bae, So-Eun; Yang, Taewoo; Ko, Gwang-Hoon; Hwang, Jeong-Ryul; Choi, Kyu Yeong; Park, Jung Eun; Lee, Jung Sup; Kim, Byeong C.; Lee, Kun Ho; Park, Sung-Gyoo
Journal of Infection and Public Health.
Jul 2024
*Background* Alzheimer’s disease (AD) is a neurodegenerative disorder influenced by age, sex, genetic factors, immune alterations, and infections. Multiple lines of evidence suggest that changes in antibody response are linked to AD pathology. *Methods* To elucidate the mechanisms underlying AD development, we investigated antibodies that target autoimmune epitopes using high-resolution epitope microarrays. Our study compared two groups: individuals with AD (n = 19) and non-demented (ND) controls (n = 19). To validate the results, we measured antibody levels in plasma samples from AD patients (n = 96), mild cognitive impairment (MCI; n = 91), and ND controls (n = 97). To further explore the invlovement of EBV, we performed epitope masking immunofluorescence microscopy analysis and tests to induce lytic replication using the B95–8 cell line. *Results* In this study, we analyzed high-resolution epitope-specific serum antibody levels in AD, revealing significant disparities in antibodies targeting multiple epitopes between the AD and control groups. Particularly noteworthy was the significant down-regulation of antibody (anti-DG#29) targeting an epitope of Epstein-Barr virus nuclear antigen 1 (EBNA1). This down-regulation increased AD risk in female patients (odds ratio up to 6.6), but not in male patients. Our investigation further revealed that the down-regulation of the antibody (anti-DG#29) is associated with EBV reactivation in AD, as indicated by the analysis of EBV VCA IgG or IgM levels. Additionally, our data demonstrated that the epitope region on EBNA1 for the antibody is hidden during the EBV lytic reactivation of B95–8 cells. *Conclusion* Our findings suggest a potential relationship of EBV in the development of AD in female. Moreover, we propose that antibodies targeting the epitope (DG#29) of EBNA1 could serve as valuable indicators of AD risk in female.

Monoclonal antibodies to growth and differentiation factor 15 (gdf-15), and uses thereof for treating cancer cachexia and cancer

WISCHHUSEN, Jörg; JUNKER, Markus; SCHÄFER, Tina; PÜHRINGER, Dirk
Oct 2015
The present invention relates to monoclonal anti-human-GDF-15 antibodies. The antibodies include chimeric antibodies and humanized antibodies. The invention also relates to monoclonal anti-human-GDF-15 antibodies including murine antibodies, chimeric antibodies and humanized antibodies for use in methods for the treatment of cancer cachexia and also for the treatment of cancer. The invention also provides pharmaceutical compositions, kits, methods and uses and cell lines capable of producing the monoclonal antibodies of the invention.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Printed peptide arrays identify prognostic TNC serumantibodies in glioblastoma patients

Mock, Andreas; Warta, Rolf; Geisenberger, Christoph; Bischoff, Ralf; Schulte, Alexander; Lamszus, Katrin; Stadler, Volker; Felgenhauer, Thomas; Schichor, Christian; Schwartz, Christoph; Matschke, Jakob; Jungk, Christine; Ahmadi, Rezvan; Sahm, Felix; Capper, David; Glass, Rainer; Tonn, Jörg-Christian; Westphal, Manfred; von Deimling, Andreas; Unterberg, Andreas; Bermejo, Justo Lorenzo; Herold-Mende, Christel
Oncotarget.
May 2015
Liquid biopsies come of age offering unexploited potential to monitor and react to tumor evolution. We developed a cost-effective assay to non-invasively determine the immune status of glioblastoma (GBM) patients. Employing newly developed printed peptide microarrays we assessed the B-cell response against tumor-associated antigens (TAAs) in 214 patients. Firstly, sera of long-term (36+ months, LTS, n=10) and short-term (6-10 months, STS, n=14) surviving patients were screened for prognostic antibodies against 1745 13-mer peptides covering known TAAs (TNC, EGFR, GLEA2, PHF3, FABP5, MAGEA3). Next, survival associations were investigated in two retrospective independent multicenter validation sets (n=61, n=129, all IDH1-wildtype). Reliability of measurements was tested using a second array technology (spotted arrays). LTS/STS screening analyses identified 106 differential antibody responses. Evaluating the Top30 peptides in validation set 1 revealed three prognostic peptides. Prediction of TNC peptide VCEDGFTGPDCAE was confirmed in a second set (p=0.043, HR=0.66 [0.44-0.99]) and was unrelated to TNC protein expression. Median signals of printed arrays correlated with pre-synthesized spotted microarrays (p<0.0002, R=0.33). Multiple survival analysis revealed independence of age, gender, KPI and MGMT status. We present a novel peptide microarray immune assay that identified increased anti-TNC VCEDGFTGPDCAE serum antibody titer as a promising non-invasive biomarker for prolonged survival.

A polyclonal antibody based immunoassay detects seven subtypes of Shiga toxin 2 produced by Escherichia coli in human and environmental samples

He, Xiaohua; Patfield, Stephanie; Hnasko, Robert; Rasooly, Reuven; Mandrell, Robert E.
PLoS ONE.
Oct 2013
BACKGROUND: Shiga toxin-producing Escherichia coli (STEC) are frequent causes of severe human diseases ranging from diarrhea to hemolytic uremic syndrome. The existing strategy for detection of STEC relies on the unique sorbitol-negative fermentation property of the O157 strains, the most commonly identified serotype has been E. coli O157. It is becoming increasingly evident, however, that numerous non-O157 STEC serotypes also cause outbreaks and severe illnesses. It is necessary to have new methods that are capable of detecting all STEC strains. METHODS AND FINDINGS: Here we describe the development of a sandwich ELISA assay for detecting both O157 and non-O157 STECs by incorporating a novel polyclonal antibody (pAb) against Stx2. The newly established immunoassay was capable of detecting Stx2a spiked in environmental samples with a limit of detection between 10 and 100 pg/mL in soil and between 100 and 500 pg/mL in feces. When applied to 36 bacterial strains isolated from human and environmental samples, this assay detected Stx2 in all strains that were confirmed to be stx2-positive by real-time PCR, demonstrating a 100% sensitivity and specificity. CONCLUSIONS: The sandwich ELISA developed in this study will enable any competent laboratory to identify and characterize Stx2-producing O157 and non-O157 strains in human and environmental samples, resulting in rapid diagnosis and patient care. The results of epitope mapping from this study will be useful for further development of a peptide-based antibody and vaccine.

Optimised ‘on demand’ protein arraying from DNA by cell free expression with the ‘DNA to Protein Array’ (DAPA) technology

Schmidt, Ronny; Cook, Elizabeth A.; Kastelic, Damjana; Taussig, Michael J.; Stoevesandt, Oda
Journal of Proteomics.
Aug 2013
We have previously described a protein arraying process based on cell free expression from DNA template arrays (DNA Array to Protein Array, DAPA). Here, we have investigated the influence of different array support coatings (Ni-NTA, Epoxy, 3D-Epoxy and Polyethylene glycol methacrylate (PEGMA)). Their optimal combination yields an increased amount of detected protein and an optimised spot morphology on the resulting protein array compared to the previously published protocol. The specificity of protein capture was improved using a tag-specific capture antibody on a protein repellent surface coating. The conditions for protein expression were optimised to yield the maximum amount of protein or the best detection results using specific monoclonal antibodies or a scaffold binder against the expressed targets. The optimised DAPA system was able to increase by threefold the expression of a representative model protein while conserving recognition by a specific antibody. The amount of expressed protein in DAPA was comparable to those of classically spotted protein arrays. Reaction conditions can be tailored to suit the application of interest. Biological significance: DAPA represents a cost effective, easy and convenient way of producing protein arrays on demand. The reported work is expected to facilitate the application of DAPA for personalized medicine and screening purposes.

Purification of High-Complexity Peptide Microarrays by Spatially Resolved Array Transfer to Gold-Coated Membranes

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Nesterov-Mueller, Alexander; Dahint, Reiner; Breitling, Frank; Bischoff, F. Ralf
Adv. Mater..
Mar 2013
A method for the one-step purification of high-complexity peptide microarrays is presented. The entire peptide library is transferred from the synthesis support to a gold coated polyvinylidenfluoride (PVDF) membrane, whereby only full-length peptides covalently couple to the receptor membrane via an N-terminally added cysteine. Highly resolved peptide transfer and purification of up to 10 000 features per cm2 is demonstrated.

Combinatorial Synthesis of Peptide Arrays onto a Microchip

Beyer, M.; Nesterov, A.; Block, I.; Konig, K.; Felgenhauer, T.; Fernandez, S.; Leibe, K.; Torralba, G.; Hausmann, M.; Trunk, U.; Lindenstruth, V.; Bischoff, F. R.; Stadler, V.; Breitling, F.
Science.
Dec 2007
Arrays promise to advance biology through parallel screening for binding partners. We show the combinatorial in situ synthesis of 40,000 peptide spots per square centimeter on a microchip. Our variant Merrifield synthesis immobilizes activated amino acids as monomers within particles, which are successively attracted by electric fields generated on each pixel electrode of the chip. With all different amino acids addressed, particles are melted at once to initiate coupling. Repetitive coupling cycles should allow for the translation of whole proteomes into arrays of overlapping peptides that could be used for proteome research and antibody profiling.

Quote form