Home » Publications

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Antigen discovery by bioinformatics analysis and peptide microarray for the diagnosis of cystic echinococcosis

Batisti Biffignandi, Gherard; Vola, Ambra; Sassera, Davide; Najafi-Fard, Saeid; Gomez Morales, Maria Angeles; Brunetti, Enrico; Teggi, Antonella; Goletti, Delia; Petrone, Linda; Tamarozzi, Francesca
PLoS Negl Trop Dis.
Apr 2023
Background Cystic echinococcosis (CE), caused by Echinococcus granulosus sensu lato, is a neglected zoonosis. Its diagnosis relies on imaging, supported by serology, while only imaging is useful for staging and follow-up. Since diagnostic tools and expertise are not widely available, new accurate and easily implementable assays for the diagnosis and follow-up of CE are highly needed. Methodology/Principal Findings We aimed to identify new E . granulosus antigens through a bioinformatics selection applied to the parasite genome, followed by peptide microarray screening and validation in ELISA, using independent panels of sera from patients with hepatic CE and clinically relevant controls. From 950 proteins selected in silico , 2,379 peptides were evaluated by microarray for IgG reactivity and eight candidates selected for validation. Reactivity to one peptide was significantly higher in the CE group (p = 0.044), but had suboptimal diagnostic accuracy. Conclusions/Significance Here we performed bioinformatics analysis and peptide microarray for antigen discovery, useful for the diagnosis of CE. Eight candidates were selected and validated. Reactivity to one peptide associated to CE but had suboptimal diagnostic accuracy. Importantly, the database developed in this study may be used to identify other antigenic candidates for CE diagnosis and follow-up.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Sensing Immune Responses with Customized Peptide Microarrays

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Breitling, Frank; Bischoff, F. Ralf
Biointerphases.
Aug 2012
The intent to solve biological and biomedical questions in high-throughput led to an immense interest in microarray technologies. Nowadays, DNA microarrays are routinely used to screen for oligonucleotide interactions within a large variety of potential interaction partners. To study interactions on the protein level with the same efficiency, protein and peptide microarrays offer similar advantages, but their production is more demanding. A new technology to produce peptide microarrays with a laser printer provides access to affordable and highly complex peptide microarrays. Such a peptide microarray can contain up to 775 peptide spots per cm², whereby the position of each peptide spot and, thus, the amino acid sequence of the corresponding peptide, is exactly known. Compared to other techniques, such as the SPOT synthesis, more features per cm² at lower costs can be synthesized which paves the way for laser printed peptide microarrays to take on roles as efficient and affordable biomedical sensors. Here, we describe the laser printer-based synthesis of peptide microarrays and focus on an application involving the blood sera of tetanus immunized individuals, indicating the potential of peptide arrays to sense immune responses.

Physical Characterization of the “Immunosignaturing Effect”

Stafford, Phillip; Halperin, Rebecca; Legutki, Joseph Bart; Magee, Dewey Mitchell; Galgiani, John; Johnston, Stephen Albert
Mol Cell Proteomics.
Apr 2012
Identifying new, effective biomarkers for diseases is proving to be a challenging problem. We have proposed that antibodies may offer a solution to this problem. The physical features and abundance of antibodies make them ideal biomarkers. Additionally, antibodies are often elicited early in the ontogeny of different chronic and infectious diseases. We previously reported that antibodies from patients with infectious disease and separately those with Alzheimer’s disease display a characteristic and reproducible immunosignature on a microarray of 10,000 random sequence peptides. Here we investigate the physical and chemical parameters underlying how immunosignaturing works. We first show that a variety of monoclonal and polyclonal antibodies raised against different classes of antigens produce distinct profiles on this microarray and the relative affinities are determined. A proposal for how antibodies bind the random sequences is tested. Sera from vaccinated mice and people suffering from a fugal infection are individually assayed to determine the complexity of signals that can be distinguished. Based on these results, we propose that this simple, general and inexpensive system could be optimized to generate a new class of antibody biomarkers for a wide variety of diseases.

Single-Molecule Detection on a Protein-Array Assay Platform for the Exposure of a Tuberculosis Antigen

Schmidt, Ronny; Jacak, Jaroslaw; Schirwitz, Christopher; Stadler, Volker; Michel, Gerd; Marmé, Nicole; Schütz, Gerhard J.; Hoheisel, Jörg D.; Knemeyer, Jens-Peter
J. Proteome Res..
Jan 2011

Combinatorial Synthesis of Peptide Arrays with a Laser Printer

Stadler, Volker; Felgenhauer, Thomas; Beyer, Mario; Fernandez, Simon; Leibe, Klaus; Güttler, Stefan; Gröning, Martin; König, Kai; Torralba, Gloria; Hausmann, Michael; Lindenstruth, Volker; Nesterov, Alexander; Block, Ines; Pipkorn, Rüdiger; Poustka, Annemarie; Bischoff, F. Ralf; Breitling, Frank
Angew. Chem. Int. Ed..
Sep 2008
Special delivery: The “freezing” of activated amino acid derivatives within solid particles enables a laser printer to deliver these “postal packages” to defined locations on a solid support with high resolution. Subsequent parallel coupling is initiated simply by melting a whole layer of 20 different amino acid particles (see schematic representation; Fmoc=9-fluorenylmethoxycarbonyl).

Combinatorial Synthesis of Peptide Arrays onto a Microchip

Beyer, M.; Nesterov, A.; Block, I.; Konig, K.; Felgenhauer, T.; Fernandez, S.; Leibe, K.; Torralba, G.; Hausmann, M.; Trunk, U.; Lindenstruth, V.; Bischoff, F. R.; Stadler, V.; Breitling, F.
Science.
Dec 2007
Arrays promise to advance biology through parallel screening for binding partners. We show the combinatorial in situ synthesis of 40,000 peptide spots per square centimeter on a microchip. Our variant Merrifield synthesis immobilizes activated amino acids as monomers within particles, which are successively attracted by electric fields generated on each pixel electrode of the chip. With all different amino acids addressed, particles are melted at once to initiate coupling. Repetitive coupling cycles should allow for the translation of whole proteomes into arrays of overlapping peptides that could be used for proteome research and antibody profiling.

Quote form