Home » Publications » Page 2

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

On‐Chip Neo‐Glycopeptide Synthesis for Multivalent Glycan Presentation

Mende, Marco; Tsouka, Alexandra; Heidepriem, Jasmin; Paris, Grigori; Mattes, Daniela S.; Eickelmann, Stephan; Bordoni, Vittorio; Wawrzinek, Robert; Fuchsberger, Felix F.; Seeberger, Peter H.; Rademacher, Christoph; Delbianco, Martina; Mallagaray, Alvaro; Loeffler, Felix F
Chem. Eur. J..
Apr 2020
Single glycan–protein interactions are often weak, such that glycan binding partners commonly utilize multiple, spatially defined binding sites to enhance binding avidity and specificity. Current array technologies usually neglect defined multivalent display. Laser-based array synthesis technology allows for flexible and rapid on-surface synthesis of different peptides. By combining this technique with click chemistry, neo-glycopeptides were produced directly on a functionalized glass slide in the microarray format. Density and spatial distribution of carbohydrates can be tuned, resulting in well-defined glycan structures for multivalent display. The two lectins concanavalin A and langerin were probed with different glycans on multivalent scaffolds, revealing strong spacing-, density-, and ligand-dependent binding. In addition, we could also measure the surface dissociation constant. This approach allows for a rapid generation, screening, and optimization of a multitude of multivalent scaffolds for glycan binding.

Optimised ‘on demand’ protein arraying from DNA by cell free expression with the ‘DNA to Protein Array’ (DAPA) technology

Schmidt, Ronny; Cook, Elizabeth A.; Kastelic, Damjana; Taussig, Michael J.; Stoevesandt, Oda
Journal of Proteomics.
Aug 2013
We have previously described a protein arraying process based on cell free expression from DNA template arrays (DNA Array to Protein Array, DAPA). Here, we have investigated the influence of different array support coatings (Ni-NTA, Epoxy, 3D-Epoxy and Polyethylene glycol methacrylate (PEGMA)). Their optimal combination yields an increased amount of detected protein and an optimised spot morphology on the resulting protein array compared to the previously published protocol. The specificity of protein capture was improved using a tag-specific capture antibody on a protein repellent surface coating. The conditions for protein expression were optimised to yield the maximum amount of protein or the best detection results using specific monoclonal antibodies or a scaffold binder against the expressed targets. The optimised DAPA system was able to increase by threefold the expression of a representative model protein while conserving recognition by a specific antibody. The amount of expressed protein in DAPA was comparable to those of classically spotted protein arrays. Reaction conditions can be tailored to suit the application of interest. Biological significance: DAPA represents a cost effective, easy and convenient way of producing protein arrays on demand. The reported work is expected to facilitate the application of DAPA for personalized medicine and screening purposes.

Purification of High-Complexity Peptide Microarrays by Spatially Resolved Array Transfer to Gold-Coated Membranes

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Nesterov-Mueller, Alexander; Dahint, Reiner; Breitling, Frank; Bischoff, F. Ralf
Adv. Mater..
Mar 2013
A method for the one-step purification of high-complexity peptide microarrays is presented. The entire peptide library is transferred from the synthesis support to a gold coated polyvinylidenfluoride (PVDF) membrane, whereby only full-length peptides covalently couple to the receptor membrane via an N-terminally added cysteine. Highly resolved peptide transfer and purification of up to 10 000 features per cm2 is demonstrated.

Quote form