Home » Publications » Page 2

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Non-invasive glioblastoma immunoprofiling by printed peptide arrays

Mock, Andreas; Herold-Mende, Christel
OncoImmunology.
Feb 2016
Immune monitoring assays for patient stratification and treatment efficacy in clinical trials are in demand. We have recently described a cost-effective non-invasive assay to determine the immune status of glioblastoma patients. Profiling antitumor serum antibodies by customized printed peptide arrays identified response against a tenascin-C (TNC) peptide as a robust prognostic biomarker.

Autoantibodies specific to estrogen receptor alpha act as estrogen agonists and their levels correlate with breast cancer cell proliferation

Maselli, Angela; Capoccia, Sara; Pugliese, Patrizia; Raggi, Carla; Cirulli, Francesca; Fabi, Alessandra; Malorni, Walter; Pierdominici, Marina; Ortona, Elena
OncoImmunology.
Feb 2016
Estrogen receptors have recently been demonstrated at the cell surface. Unlike nuclear receptors, they are able to trigger rapid responses inside the cells. In this study, we evaluated the presence and the possible role of autoantibodies specific to estrogen receptor (anti-ER Abs) in the peripheral blood of breast cancer patients. Anti-ERα Abs were detectable in 22/48 (46%) patients’ sera and their levels positively correlated with the percentage of Ki-67-positive breast cancer cells. Anti-ERα Abs purified from breast cancer patients’ sera were able: (i) to recognize ERα epitopes expressed at the cell surface of ER-positive breast cancer cells, (ii) to trigger rapid extracellular signal-regulated kinase (ERK) phosphorylation, and (iii) to induce cell proliferation. Our results suggest that anti-ERα Abs can act as estrogen agonists playing a pathogenetic role as breast cancer-promoting factors. These autoantibodies could also be considered as possible peripheral blood biomarkers indicative of the breast cancer growth potential.

Monoclonal antibodies to growth and differentiation factor 15 (gdf-15), and uses thereof for treating cancer cachexia and cancer

WISCHHUSEN, Jörg; JUNKER, Markus; SCHÄFER, Tina; PÜHRINGER, Dirk
Oct 2015
The present invention relates to monoclonal anti-human-GDF-15 antibodies. The antibodies include chimeric antibodies and humanized antibodies. The invention also relates to monoclonal anti-human-GDF-15 antibodies including murine antibodies, chimeric antibodies and humanized antibodies for use in methods for the treatment of cancer cachexia and also for the treatment of cancer. The invention also provides pharmaceutical compositions, kits, methods and uses and cell lines capable of producing the monoclonal antibodies of the invention.

Printed peptide arrays identify prognostic TNC serumantibodies in glioblastoma patients

Mock, Andreas; Warta, Rolf; Geisenberger, Christoph; Bischoff, Ralf; Schulte, Alexander; Lamszus, Katrin; Stadler, Volker; Felgenhauer, Thomas; Schichor, Christian; Schwartz, Christoph; Matschke, Jakob; Jungk, Christine; Ahmadi, Rezvan; Sahm, Felix; Capper, David; Glass, Rainer; Tonn, Jörg-Christian; Westphal, Manfred; von Deimling, Andreas; Unterberg, Andreas; Bermejo, Justo Lorenzo; Herold-Mende, Christel
Oncotarget.
May 2015
Liquid biopsies come of age offering unexploited potential to monitor and react to tumor evolution. We developed a cost-effective assay to non-invasively determine the immune status of glioblastoma (GBM) patients. Employing newly developed printed peptide microarrays we assessed the B-cell response against tumor-associated antigens (TAAs) in 214 patients. Firstly, sera of long-term (36+ months, LTS, n=10) and short-term (6-10 months, STS, n=14) surviving patients were screened for prognostic antibodies against 1745 13-mer peptides covering known TAAs (TNC, EGFR, GLEA2, PHF3, FABP5, MAGEA3). Next, survival associations were investigated in two retrospective independent multicenter validation sets (n=61, n=129, all IDH1-wildtype). Reliability of measurements was tested using a second array technology (spotted arrays). LTS/STS screening analyses identified 106 differential antibody responses. Evaluating the Top30 peptides in validation set 1 revealed three prognostic peptides. Prediction of TNC peptide VCEDGFTGPDCAE was confirmed in a second set (p=0.043, HR=0.66 [0.44-0.99]) and was unrelated to TNC protein expression. Median signals of printed arrays correlated with pre-synthesized spotted microarrays (p<0.0002, R=0.33). Multiple survival analysis revealed independence of age, gender, KPI and MGMT status. We present a novel peptide microarray immune assay that identified increased anti-TNC VCEDGFTGPDCAE serum antibody titer as a promising non-invasive biomarker for prolonged survival.

A polyclonal antibody based immunoassay detects seven subtypes of Shiga toxin 2 produced by Escherichia coli in human and environmental samples

He, Xiaohua; Patfield, Stephanie; Hnasko, Robert; Rasooly, Reuven; Mandrell, Robert E.
PLoS ONE.
Oct 2013
BACKGROUND: Shiga toxin-producing Escherichia coli (STEC) are frequent causes of severe human diseases ranging from diarrhea to hemolytic uremic syndrome. The existing strategy for detection of STEC relies on the unique sorbitol-negative fermentation property of the O157 strains, the most commonly identified serotype has been E. coli O157. It is becoming increasingly evident, however, that numerous non-O157 STEC serotypes also cause outbreaks and severe illnesses. It is necessary to have new methods that are capable of detecting all STEC strains. METHODS AND FINDINGS: Here we describe the development of a sandwich ELISA assay for detecting both O157 and non-O157 STECs by incorporating a novel polyclonal antibody (pAb) against Stx2. The newly established immunoassay was capable of detecting Stx2a spiked in environmental samples with a limit of detection between 10 and 100 pg/mL in soil and between 100 and 500 pg/mL in feces. When applied to 36 bacterial strains isolated from human and environmental samples, this assay detected Stx2 in all strains that were confirmed to be stx2-positive by real-time PCR, demonstrating a 100% sensitivity and specificity. CONCLUSIONS: The sandwich ELISA developed in this study will enable any competent laboratory to identify and characterize Stx2-producing O157 and non-O157 strains in human and environmental samples, resulting in rapid diagnosis and patient care. The results of epitope mapping from this study will be useful for further development of a peptide-based antibody and vaccine.

Quote form