Home » Publications » Page 2

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

A public antibody lineage that potently inhibits malaria infection through dual binding to the circumsporozoite protein

Tan, Joshua; Sack, Brandon K; Oyen, David; Zenklusen, Isabelle; Piccoli, Luca; Barbieri, Sonia; Foglierini, Mathilde; Fregni, Chiara Silacci; Marcandalli, Jessica; Jongo, Said; Abdulla, Salim; Perez, Laurent; Corradin, Giampietro; Varani, Luca; Sallusto, Federica; Sim, Betty Kim Lee; Hoffman, Stephen L; Kappe, Stefan H I; Daubenberger, Claudia; Wilson, Ian A; Lanzavecchia, Antonio
Nat Med.
Mar 2018
Immunization with attenuated Plasmodium falciparum sporozoites (PfSPZs) has been shown to be protective against malaria, but the features of the antibody response induced by this treatment remain unclear. To investigate this response in detail, we isolated IgM and IgG monoclonal antibodies from Tanzanian volunteers who were immunized with repeated injection of Sanaria PfSPZ Vaccine and who were found to be protected from controlled human malaria infection with infectious homologous PfSPZs. All isolated IgG monoclonal antibodies bound to P. falciparum circumsporozoite protein (PfCSP) and recognized distinct epitopes in its N terminus, NANP-repeat region, and C terminus. Strikingly, the most effective antibodies, as determined in a humanized mouse model, bound not only to the repeat region, but also to a minimal peptide at the PfCSP N-terminal junction that is not in the RTS,S vaccine. These dual-specific antibodies were isolated from different donors and were encoded by VH3-30 or VH3-33 alleles that encode tryptophan or arginine at position 52. Using structural and mutational data, we describe the elements required for germline recognition and affinity maturation. Our study provides potent neutralizing antibodies and relevant information for lineage-targeted vaccine design and immunization strategies.

Evaluation of the Diagnostic Performance of Onchocerca volvulus Linear Epitopes in a Peptide Enzyme-Linked Immunosorbent Assay

Lagatie, Ole; Verheyen, Ann; Nijs, Erik; Van Dorst, Bieke; Batsa Debrah, Linda; Debrah, Alex; Supali, Taniawati; Sartono, Erliyani; Stuyver, Lieven J.
Diagnostic tools for the detection of infection with Onchocerca volvulus are presently limited to microfilaria detection in skin biopsies and serological assessment using the Ov16 immunoglobulin G4 (IgG4) rapid test, both of which have limited sensitivity. We have investigated the diagnostic performance of a peptide enzyme-linked immunosorbent assay (ELISA) based on immunodominant linear epitopes previously discovered. Peptides that were used in these assays were designated O. volvulus motif peptides (OvMP): OvMP-1 (VSV-EPVTTQET-VSV), OvMP-2 (VSV-KDGEDK-VSV), OvMP-3 (VSV-QTSNLD-VSV), and the combination of the latter two, OvMP-23 (VSV-KDGEDK-VSV-QTSNLD-VSV). Sensitivity (O. volvulus infection), specificity (non-helminth infections), and cross-reactivity (helminth infections) were determined using several panels of clinical plasma isolates. OvMP-1 was found to be very sensitive (100%) and specific (98.7%), but showed substantial cross-reactivity with other helminths. Of the other peptides, OvMP-23 was the most promising peptide with a sensitivity of 92.7%, a specificity of 100%, and a cross-reactivity of 6%. It was also demonstrated that these peptides were immunoreactive to IgG but not IgG4, and there is no correlation with the Ov16 IgG4 status, making them promising candidates to complement this already available test. Combination of the Ov16 IgG4 rapid test and OvMP-23 peptide ELISA led to a sensitivity of 97.3% for the detection of O. volvulus infection, without compromising specificity and with minimal impact on cross-reactivity. The available results open the opportunity for a clinical utility use case discussion for improved O. volvulus epidemiological mapping.

A Trifunctional Linker for Purified 3D Assembled Peptide Structure Arrays

Mattes, Daniela S.; Rentschler, Simone; Foertsch, Tobias C.; Münch, Stephan W.; Loeffler, Felix F.; Nesterov-Mueller, Alexander; Bräse, Stefan; Breitling, Frank
Small Methods.
Feb 2018
Microarrays are an important tool in modern research that allow the rapid screening of many different interactions simultaneously. Peptide arrays, which bear different peptides arranged in separate spots, permit high-throughput screening to investigate linear and cyclic binding sites. To study conformational or discontinuous binding sites, protein arrays are the major choice. However, the tremendous costs for the generation of high-density protein arrays of high purity restrict progress in protein research. Therefore, peptide-based arrays, which can mimic assembled peptide structures, have an enormous potential. Here, a method is presented to create such structures in the array format as an alternative to protein arrays. A trifunctional linker is developed with an azide, a protected alkyne, and a carboxyl group, which can react with two or three different peptides. Due to the spatial proximity, the peptides interact and can form an assembled peptide structure. As a proof of concept, assembled peptide structures are demonstrated on beads and on a polymer surface and the approach can be validated via matrix-assisted laser desorption/ionization spectrometry. Furthermore, a multistep transfer of peptide arrays is shown, generating purified assembled peptide structure arrays in high density.

Development and characterization of a human monoclonal antibody targeting the N-terminal region of hepatitis C virus envelope glycoprotein E1

Mesalam, Ahmed Atef; Desombere, Isabelle; Farhoudi, Ali; Van Houtte, Freya; Verhoye, Lieven; Ball, Jonathan; Dubuisson, Jean; Foung, Steven K.H.; Patel, Arvind H.; Persson, Mats A.A.; Leroux-Roels, Geert; Meuleman, Philip
Virology.
Jan 2018
Monoclonal antibodies (mAbs) targeting the hepatitis C virus (HCV) envelope have been raised mainly against envelope protein 2 (E2), while the antigenic epitopes of envelope protein 1 (E1) are not fully identified. Here we describe the detailed characterization of a human mAb, designated A6, generated from an HCV genotype 1b infected patient. ELISA results showed reactivity of mAb A6 to full-length HCV E1E2 of genotypes 1a, 1b and 2a. Epitope mapping identified a region spanning amino acids 230–239 within the N-terminal region of E1 as critical for binding. Antibody binding to this epitope was not conformation dependent. Neutralization assays showed that mAb A6 lacks neutralizing capacity and does not interfere with the activity of known neutralizing antibodies. In summary, mAb A6 is an important tool to study the structure and function of E1 within the viral envelope, a crucial step in the development of an effective prophylactic HCV vaccine.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Monoclonal antibodies to HLA-E bind epitopes carried by unfolded β 2 m-free heavy chains: Molecular immunology

Tremante, Elisa; Lo Monaco, Elisa; Ingegnere, Tiziano; Sampaoli, Camilla; Fraioli, Rocco; Giacomini, Patrizio
Eur. J. Immunol..
Aug 2015
Since HLA-E heavy chains accumulate free of their light β2-microglobulin (β2m) subunit, raising mAbs to folded HLA-E heterodimers has been difficult, and mAb characterization has been controversial. Herein, mAb W6/32 and 5 HLA-E-restricted mAbs (MEM-E/02, MEM-E/07, MEM-E/08, DT9, and 3D12) were tested on denatured, acid-treated, and natively folded (both β2m-associated and β2m-free) HLA-E molecules. Four distinct conformations were detected, including unusual, partially folded (and yet β2m-free) heavy chains reactive with mAb DT9. In contrast with previous studies, epitope mapping and substitution scan on thousands of overlapping peptides printed on microchips revealed that mAbs MEM-E/02, MEM-E/07, and MEM-E/08 bind three distinct α1 and α2 domain epitopes. All three epitopes are linear since they span just 4–6 residues and are “hidden” in folded HLA-E heterodimers. They contain at least one HLA-E-specific residue that cannot be replaced by single substitutions with polymorphic HLA-A, HLA-B, HLA-C, HLA-F, and HLA-G residues. Finally, also the MEM-E/02 and 3D12 epitopes are spatially distinct. In summary, HLA-E-specific residues are dominantly immunogenic, but only when heavy chains are locally unfolded. Consequently, the available mAbs fail to selectively bind conformed HLA-E heterodimers, and HLA-E expression may have been inaccurately assessed in some previous oncology, reproductive immunology, virology, and transplantation studies.

Sensing Immune Responses with Customized Peptide Microarrays

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Breitling, Frank; Bischoff, F. Ralf
Biointerphases.
Aug 2012
The intent to solve biological and biomedical questions in high-throughput led to an immense interest in microarray technologies. Nowadays, DNA microarrays are routinely used to screen for oligonucleotide interactions within a large variety of potential interaction partners. To study interactions on the protein level with the same efficiency, protein and peptide microarrays offer similar advantages, but their production is more demanding. A new technology to produce peptide microarrays with a laser printer provides access to affordable and highly complex peptide microarrays. Such a peptide microarray can contain up to 775 peptide spots per cm², whereby the position of each peptide spot and, thus, the amino acid sequence of the corresponding peptide, is exactly known. Compared to other techniques, such as the SPOT synthesis, more features per cm² at lower costs can be synthesized which paves the way for laser printed peptide microarrays to take on roles as efficient and affordable biomedical sensors. Here, we describe the laser printer-based synthesis of peptide microarrays and focus on an application involving the blood sera of tetanus immunized individuals, indicating the potential of peptide arrays to sense immune responses.

Physical Characterization of the “Immunosignaturing Effect”

Stafford, Phillip; Halperin, Rebecca; Legutki, Joseph Bart; Magee, Dewey Mitchell; Galgiani, John; Johnston, Stephen Albert
Mol Cell Proteomics.
Apr 2012
Identifying new, effective biomarkers for diseases is proving to be a challenging problem. We have proposed that antibodies may offer a solution to this problem. The physical features and abundance of antibodies make them ideal biomarkers. Additionally, antibodies are often elicited early in the ontogeny of different chronic and infectious diseases. We previously reported that antibodies from patients with infectious disease and separately those with Alzheimer’s disease display a characteristic and reproducible immunosignature on a microarray of 10,000 random sequence peptides. Here we investigate the physical and chemical parameters underlying how immunosignaturing works. We first show that a variety of monoclonal and polyclonal antibodies raised against different classes of antigens produce distinct profiles on this microarray and the relative affinities are determined. A proposal for how antibodies bind the random sequences is tested. Sera from vaccinated mice and people suffering from a fugal infection are individually assayed to determine the complexity of signals that can be distinguished. Based on these results, we propose that this simple, general and inexpensive system could be optimized to generate a new class of antibody biomarkers for a wide variety of diseases.

Quote form