Home » Publications » Page 9

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Showing most recent

Characterization of a sandwich ELISA for the quantification of all human periostin isoforms

Gadermaier, Elisabeth; Tesarz, Manfred; Suciu, Andreea Ana-Maria; Wallwitz, Jacqueline; Berg, Gabriela; Himmler, Gottfried
J Clin Lab Anal.
Feb 2018
Background Periostin (osteoblast-specific factor OSF-2) is a secreted protein occurring in seven known isoforms, and it is involved in a variety of biological processes in osteology, tissue repair, oncology, cardiovascular and respiratory systems or allergic manifestations. To analyze functional aspects of periostin, or the ability of periostin as potential biomarker in physiological and pathological conditions, there is the need for a precise, well-characterized assay that detects periostin in peripheral blood. Methods In this study the development of a sandwich ELISA using monoclonal and affinity-purified polyclonal anti-human periostin antibodies was described. Antibodies were characterized by mapping of linear epitopes with microarray technology, and by analyzing cross-reactive binding to human periostin isoforms with western blot. The assay was validated according to ICH/EMEA guidelines. Results The monoclonal coating antibody binds to a linear epitope conserved between the isoforms. The polyclonal detection antibody recognizes multiple conserved linear epitopes. Therefore, the periostin ELISA detects all known human periostin isoforms. The assay is optimized for human serum and plasma and covers a calibration range between 125 and 4000 pmol/L for isoform 1. Assay characteristics, such as precision (intra-assay: ≤3%, inter-assay: ≤6%), spike-recovery (83%-106%), dilution linearity (95%-126%), as well as sample stability meet the standards of acceptance. Periostin levels of apparently healthy individuals are 864±269 pmol/L (serum) and 817±170 pmol/L (plasma) respectively. Conclusion This ELISA is a reliable and accurate tool for determination of all currently known periostin isoforms in human healthy and diseased samples.

Development and characterization of a human monoclonal antibody targeting the N-terminal region of hepatitis C virus envelope glycoprotein E1

Mesalam, Ahmed Atef; Desombere, Isabelle; Farhoudi, Ali; Van Houtte, Freya; Verhoye, Lieven; Ball, Jonathan; Dubuisson, Jean; Foung, Steven K.H.; Patel, Arvind H.; Persson, Mats A.A.; Leroux-Roels, Geert; Meuleman, Philip
Virology.
Jan 2018
Monoclonal antibodies (mAbs) targeting the hepatitis C virus (HCV) envelope have been raised mainly against envelope protein 2 (E2), while the antigenic epitopes of envelope protein 1 (E1) are not fully identified. Here we describe the detailed characterization of a human mAb, designated A6, generated from an HCV genotype 1b infected patient. ELISA results showed reactivity of mAb A6 to full-length HCV E1E2 of genotypes 1a, 1b and 2a. Epitope mapping identified a region spanning amino acids 230–239 within the N-terminal region of E1 as critical for binding. Antibody binding to this epitope was not conformation dependent. Neutralization assays showed that mAb A6 lacks neutralizing capacity and does not interfere with the activity of known neutralizing antibodies. In summary, mAb A6 is an important tool to study the structure and function of E1 within the viral envelope, a crucial step in the development of an effective prophylactic HCV vaccine.

Anti-apoc3 antibodies and methods of use thereof

Dasilva-Jardine, Paul; Haard, Hans De; Landro, James A.
Jan 2018

Inmunotecnología y sus aplicaciones

Álvarez-Vallina, Luis; González Fernández, África; Magadán Mompó, Susana; Ramírez, Natalia; Reche, Pedro A; Toyos, J. R. de los; Ybarra, Gabriel
Jan 2018

Peptide Arrays with a Chip

Nesterov, Alexander; Dörsam, Edgar; Cheng, Yun-Chien; Schirwitz, Christopher; Märkle, Frieder; Löffler, Felix; König, Kai; Stadler, Volker; Bischoff, Ralf; Breitling, Frank
Today, lithographic methods enable combinatorial synthesis of >50,000 oligonucleotides per cm2, an advance that has revolutionized the whole field of genomics. A similar development is expected for the field of proteomics, provided that affordable, very high-density peptide arrays are available. However, peptide arrays lag behind oligonucleotide arrays. This is mainly due to the monomer-by-monomer repeated consecutive coupling of 20 different amino acids associated with lithography, which adds up to an excessive number of coupling cycles. A combinatorial synthesis based on electrically charged solid amino acid particles resolves this problem. A computer chip consecutively addresses the different charged particles to a solid support, where, when completed, the whole layer of solid amino acid particles is melted at once. This frees hitherto immobilized amino acids to couple all 20 different amino acids in one single coupling reaction to the support. The method should allow for the translation of entire genomes into a set of overlapping peptides to be used in proteome research.

Quote form