Home » Publications » Page 2

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Increased neutralization and IgG epitope identification after MVA-MERS-S booster vaccination against Middle East respiratory syndrome

Fathi, Anahita; Dahlke, Christine; Krähling, Verena; Kupke, Alexandra; Okba, Nisreen M. A.; Raadsen, Matthijs P.; Heidepriem, Jasmin; Müller, Marcel A.; Paris, Grigori; Lassen, Susan; Klüver, Michael; Volz, Asisa; Koch, Till; Ly, My L.; Friedrich, Monika; Fux, Robert; Tscherne, Alina; Kalodimou, Georgia; Schmiedel, Stefan; Corman, Victor M.; Hesterkamp, Thomas; Drosten, Christian; Loeffler, Felix F.; Haagmans, Bart L.; Sutter, Gerd; Becker, Stephan; Addo, Marylyn M.
Vaccine development is essential for pandemic preparedness. We previously conducted a Phase 1 clinical trial of the vector vaccine candidate MVA-MERS-S against the Middle East respiratory syndrome coronavirus (MERS-CoV), expressing its full spike glycoprotein (MERS-CoV-S), as a homologous two-dose regimen (Days 0 and 28). Here, we evaluate a third vaccination with MVA-MERS-S in a subgroup of trial participants one year after primary immunization. A booster vaccination with MVA-MERS-S is safe and well-tolerated. Both binding and neutralizing anti-MERS-CoV antibody titers increase substantially in all participants and exceed maximum titers observed after primary immunization more than 10-fold. We identify four immunogenic IgG epitopes, located in the receptor-binding domain (RBD, n=1) and the S2 subunit (n=3) of MERS-CoV-S. The level of baseline anti-human coronavirus antibody titers does not impact the generation of anti-MERS-CoV antibody responses. Our data support the rationale of a booster vaccination with MVA-MERS-S and encourage further investigation in larger trials.

Scoping review of the applications of peptide microarrays on the fight against human infections

Vengesai, Arthur; Kasambala, Maritha; Mutandadzi, Hamlet; Mduluza-Jokonya, Tariro L.; Mduluza, Takafira; Naicker, Thajasvarie
PLoS ONE.
Jan 2022
Introduction This scoping review explores the use of peptide microarrays in the fight against infectious diseases. The research domains explored included the use of peptide microarrays in the mapping of linear B-cell and T cell epitopes, antimicrobial peptide discovery, immunosignature characterisation and disease immunodiagnostics. This review also provides a short overview of peptide microarray synthesis. Methods Electronic databases were systematically searched to identify relevant studies. The review was conducted using the Joanna Briggs Institute methodology for scoping reviews and data charting was performed using a predefined form. The results were reported by narrative synthesis in line with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews guidelines. Results Ninety-five articles from 103 studies were included in the final data charting process. The majority (92. 0%) of the articles were published during 2010–2020 and were mostly from Europe (44.2%) and North America (34.7%). The findings were from the investigation of viral (45.6%), bacterial (32. 0%), parasitic (23.3%) and fungal (2. 0%) infections. Out of the serological studies, IgG was the most reported antibody type followed by IgM. The largest portion of the studies (77.7%) were related to mapping B-cell linear epitopes, 5.8% were on diagnostics, 5.8% reported on immunosignature characterisation and 8.7% reported on viral and bacterial cell binding assays. Two studies reported on T-cell epitope profiling. Conclusion The most important application of peptide microarrays was found to be B-cell epitope mapping or antibody profiling to identify diagnostic and vaccine targets. Immunosignatures identified by random peptide microarrays were found to be applied in the diagnosis of infections and interrogation of vaccine responses. The analysis of the interactions of random peptide microarrays with bacterial and viral cells using binding assays enabled the identification of antimicrobial peptides. Peptide microarray arrays were also used for T-cell linear epitope mapping which may provide more information for the design of peptide-based vaccines and for the development of diagnostic reagents.

Analysis of the Immune Response and Identification of Antibody Epitopes Against the Sigma C Protein of Avian Orthoreovirus Following Immunization with Live or Inactivated Vaccines

Dawe, W. H.; Kapczynski, D. R.; Linnemann, E. G.; Gauthiersloan, V. R.; Sellers, H. S.
Avian Diseases.
Jan 2022

Protein microarrays for COVID-19 research: Biomarker discovery, humoral response, and vaccine targets

Acharjee, Arup; Barpanda, Abhilash; Ren, Jing; Yu, Xiaobo
Of all the technological interventions used to probe the COVID-19 biological sample, microarrays have provided unique information about the biology of SARS-CoV-2 infection in the greatest of detail. Protein microarrays are available in various formats such as protein microarray, antibody microarray, and peptide microarrays. These provide an attractive format to study host response against infection, with its straightforward sample preparation strategy and easy result analysis pipelines. Microarray technology either uses antibodies against hundreds of proteins to study host proteins or scans immunogenic peptides of the pathogen in a microarray panel of the pathogen proteome. It can be used to study the humoral immune response against antigenic proteins of the SARS-CoV-2 virus, host proteomic alterations due to the infection. The SARS-CoV-2 peptide array can be used for the accurate detection of antigenic determinants for vaccine design. This chapter summarizes the different types of protein and peptide microarray and their use in COVID-19 biomarker discovery, disease management, vaccine design, etc., for better management of COVID-19.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Monoclonal antibodies to HLA-E bind epitopes carried by unfolded β 2 m-free heavy chains: Molecular immunology

Tremante, Elisa; Lo Monaco, Elisa; Ingegnere, Tiziano; Sampaoli, Camilla; Fraioli, Rocco; Giacomini, Patrizio
Eur. J. Immunol..
Aug 2015
Since HLA-E heavy chains accumulate free of their light β2-microglobulin (β2m) subunit, raising mAbs to folded HLA-E heterodimers has been difficult, and mAb characterization has been controversial. Herein, mAb W6/32 and 5 HLA-E-restricted mAbs (MEM-E/02, MEM-E/07, MEM-E/08, DT9, and 3D12) were tested on denatured, acid-treated, and natively folded (both β2m-associated and β2m-free) HLA-E molecules. Four distinct conformations were detected, including unusual, partially folded (and yet β2m-free) heavy chains reactive with mAb DT9. In contrast with previous studies, epitope mapping and substitution scan on thousands of overlapping peptides printed on microchips revealed that mAbs MEM-E/02, MEM-E/07, and MEM-E/08 bind three distinct α1 and α2 domain epitopes. All three epitopes are linear since they span just 4–6 residues and are “hidden” in folded HLA-E heterodimers. They contain at least one HLA-E-specific residue that cannot be replaced by single substitutions with polymorphic HLA-A, HLA-B, HLA-C, HLA-F, and HLA-G residues. Finally, also the MEM-E/02 and 3D12 epitopes are spatially distinct. In summary, HLA-E-specific residues are dominantly immunogenic, but only when heavy chains are locally unfolded. Consequently, the available mAbs fail to selectively bind conformed HLA-E heterodimers, and HLA-E expression may have been inaccurately assessed in some previous oncology, reproductive immunology, virology, and transplantation studies.

Sensing Immune Responses with Customized Peptide Microarrays

Schirwitz, Christopher; Loeffler, Felix F.; Felgenhauer, Thomas; Stadler, Volker; Breitling, Frank; Bischoff, F. Ralf
Biointerphases.
Aug 2012
The intent to solve biological and biomedical questions in high-throughput led to an immense interest in microarray technologies. Nowadays, DNA microarrays are routinely used to screen for oligonucleotide interactions within a large variety of potential interaction partners. To study interactions on the protein level with the same efficiency, protein and peptide microarrays offer similar advantages, but their production is more demanding. A new technology to produce peptide microarrays with a laser printer provides access to affordable and highly complex peptide microarrays. Such a peptide microarray can contain up to 775 peptide spots per cm², whereby the position of each peptide spot and, thus, the amino acid sequence of the corresponding peptide, is exactly known. Compared to other techniques, such as the SPOT synthesis, more features per cm² at lower costs can be synthesized which paves the way for laser printed peptide microarrays to take on roles as efficient and affordable biomedical sensors. Here, we describe the laser printer-based synthesis of peptide microarrays and focus on an application involving the blood sera of tetanus immunized individuals, indicating the potential of peptide arrays to sense immune responses.

Physical Characterization of the “Immunosignaturing Effect”

Stafford, Phillip; Halperin, Rebecca; Legutki, Joseph Bart; Magee, Dewey Mitchell; Galgiani, John; Johnston, Stephen Albert
Mol Cell Proteomics.
Apr 2012
Identifying new, effective biomarkers for diseases is proving to be a challenging problem. We have proposed that antibodies may offer a solution to this problem. The physical features and abundance of antibodies make them ideal biomarkers. Additionally, antibodies are often elicited early in the ontogeny of different chronic and infectious diseases. We previously reported that antibodies from patients with infectious disease and separately those with Alzheimer’s disease display a characteristic and reproducible immunosignature on a microarray of 10,000 random sequence peptides. Here we investigate the physical and chemical parameters underlying how immunosignaturing works. We first show that a variety of monoclonal and polyclonal antibodies raised against different classes of antigens produce distinct profiles on this microarray and the relative affinities are determined. A proposal for how antibodies bind the random sequences is tested. Sera from vaccinated mice and people suffering from a fugal infection are individually assayed to determine the complexity of signals that can be distinguished. Based on these results, we propose that this simple, general and inexpensive system could be optimized to generate a new class of antibody biomarkers for a wide variety of diseases.

Quote form