Home » Publications » Page 3

Publications

Discover how PEPperPRINT Peptide Microarray products have been used in different fields of research.

Characterization of a sandwich ELISA for the quantification of all human periostin isoforms

Gadermaier, Elisabeth; Tesarz, Manfred; Suciu, Andreea Ana-Maria; Wallwitz, Jacqueline; Berg, Gabriela; Himmler, Gottfried
J Clin Lab Anal.
Feb 2018
Background Periostin (osteoblast-specific factor OSF-2) is a secreted protein occurring in seven known isoforms, and it is involved in a variety of biological processes in osteology, tissue repair, oncology, cardiovascular and respiratory systems or allergic manifestations. To analyze functional aspects of periostin, or the ability of periostin as potential biomarker in physiological and pathological conditions, there is the need for a precise, well-characterized assay that detects periostin in peripheral blood. Methods In this study the development of a sandwich ELISA using monoclonal and affinity-purified polyclonal anti-human periostin antibodies was described. Antibodies were characterized by mapping of linear epitopes with microarray technology, and by analyzing cross-reactive binding to human periostin isoforms with western blot. The assay was validated according to ICH/EMEA guidelines. Results The monoclonal coating antibody binds to a linear epitope conserved between the isoforms. The polyclonal detection antibody recognizes multiple conserved linear epitopes. Therefore, the periostin ELISA detects all known human periostin isoforms. The assay is optimized for human serum and plasma and covers a calibration range between 125 and 4000 pmol/L for isoform 1. Assay characteristics, such as precision (intra-assay: ≤3%, inter-assay: ≤6%), spike-recovery (83%-106%), dilution linearity (95%-126%), as well as sample stability meet the standards of acceptance. Periostin levels of apparently healthy individuals are 864±269 pmol/L (serum) and 817±170 pmol/L (plasma) respectively. Conclusion This ELISA is a reliable and accurate tool for determination of all currently known periostin isoforms in human healthy and diseased samples.

Anti-apoc3 antibodies and methods of use thereof

Dasilva-Jardine, Paul; Haard, Hans De; Landro, James A.
Jan 2018

Monoclonal antibodies to growth and differentiation factor 15 (gdf-15), and uses thereof for treating cancer cachexia and cancer

WISCHHUSEN, Jörg; JUNKER, Markus; SCHÄFER, Tina; PÜHRINGER, Dirk
Oct 2015
The present invention relates to monoclonal anti-human-GDF-15 antibodies. The antibodies include chimeric antibodies and humanized antibodies. The invention also relates to monoclonal anti-human-GDF-15 antibodies including murine antibodies, chimeric antibodies and humanized antibodies for use in methods for the treatment of cancer cachexia and also for the treatment of cancer. The invention also provides pharmaceutical compositions, kits, methods and uses and cell lines capable of producing the monoclonal antibodies of the invention.

Spot peptide arrays and SPR measurements: throughput and quantification in antibody selectivity studies: Peptide Arrays for Antibody Selectivity Studies

Vernet, Thierry; Choulier, Laurence; Nominé, Yves; Bellard, Laure; Baltzinger, Mireille; Travé, Gilles; Altschuh, Danièle
J. Mol. Recognit..
Oct 2015
Antibody selectivity represents a major issue in the development of efficient immuno-therapeutics and detection assays. Its description requires a comparison of the affinities of the antibody for a significant number of antigen variants. In the case of peptide antigens, this task can now be addressed to a significant level of details owing to improvements in spot peptide array technologies. They allow the high-throughput mutational analysis of peptides with, depending on assay design, an evaluation of binding stabilities. Here, we examine the cross-reactive capacity of an antibody fragment using the PEPperCHIP® technology platform (PEPperPRINT GmbH, Heidelberg, Germany; >8800 peptides per microarray) combined with the surface plasmon resonance characterization (Biacore® technology; GE-Healthcare Biacore, Uppsala, Sweden) of a subset of interactions. ScFv1F4 recognizes the N-terminal end of oncoprotein E6 of human papilloma virus 16. The spot permutation analysis (i.e. each position substituted by all amino acids except cysteine) of the wild type decapeptide (sequence 6TAMFQDPQER15) and of 15 variants thereof defined the optimal epitope and provided a ranking for variant recognition. The SPR affinity measurements mostly validated the ranking of complex stabilities deduced from array data and defined the sensitivity of spot fluorescence intensities, bringing further insight into the conditions for cross-reactivity. Our data demonstrate the importance of throughput and quantification in the assessment of antibody selectivity.

Printed peptide arrays identify prognostic TNC serumantibodies in glioblastoma patients

Mock, Andreas; Warta, Rolf; Geisenberger, Christoph; Bischoff, Ralf; Schulte, Alexander; Lamszus, Katrin; Stadler, Volker; Felgenhauer, Thomas; Schichor, Christian; Schwartz, Christoph; Matschke, Jakob; Jungk, Christine; Ahmadi, Rezvan; Sahm, Felix; Capper, David; Glass, Rainer; Tonn, Jörg-Christian; Westphal, Manfred; von Deimling, Andreas; Unterberg, Andreas; Bermejo, Justo Lorenzo; Herold-Mende, Christel
Oncotarget.
May 2015
Liquid biopsies come of age offering unexploited potential to monitor and react to tumor evolution. We developed a cost-effective assay to non-invasively determine the immune status of glioblastoma (GBM) patients. Employing newly developed printed peptide microarrays we assessed the B-cell response against tumor-associated antigens (TAAs) in 214 patients. Firstly, sera of long-term (36+ months, LTS, n=10) and short-term (6-10 months, STS, n=14) surviving patients were screened for prognostic antibodies against 1745 13-mer peptides covering known TAAs (TNC, EGFR, GLEA2, PHF3, FABP5, MAGEA3). Next, survival associations were investigated in two retrospective independent multicenter validation sets (n=61, n=129, all IDH1-wildtype). Reliability of measurements was tested using a second array technology (spotted arrays). LTS/STS screening analyses identified 106 differential antibody responses. Evaluating the Top30 peptides in validation set 1 revealed three prognostic peptides. Prediction of TNC peptide VCEDGFTGPDCAE was confirmed in a second set (p=0.043, HR=0.66 [0.44-0.99]) and was unrelated to TNC protein expression. Median signals of printed arrays correlated with pre-synthesized spotted microarrays (p<0.0002, R=0.33). Multiple survival analysis revealed independence of age, gender, KPI and MGMT status. We present a novel peptide microarray immune assay that identified increased anti-TNC VCEDGFTGPDCAE serum antibody titer as a promising non-invasive biomarker for prolonged survival.

Combinatorial Synthesis of Peptide Arrays with a Laser Printer

Stadler, Volker; Felgenhauer, Thomas; Beyer, Mario; Fernandez, Simon; Leibe, Klaus; Güttler, Stefan; Gröning, Martin; König, Kai; Torralba, Gloria; Hausmann, Michael; Lindenstruth, Volker; Nesterov, Alexander; Block, Ines; Pipkorn, Rüdiger; Poustka, Annemarie; Bischoff, F. Ralf; Breitling, Frank
Angew. Chem. Int. Ed..
Sep 2008
Special delivery: The “freezing” of activated amino acid derivatives within solid particles enables a laser printer to deliver these “postal packages” to defined locations on a solid support with high resolution. Subsequent parallel coupling is initiated simply by melting a whole layer of 20 different amino acid particles (see schematic representation; Fmoc=9-fluorenylmethoxycarbonyl).

Quote form